EM-Storr vacuum sample storage container for 19 x Ø12.7mm pin stubs EM-Storr vacuum sample storage container for 60 TEM grids   EM-Storr vacuum sample storage container for 19 x Ø15mm Hitachi stubs

Description

The EM-Tec EM-Storr vacuum sample storage container has been specifically developed to store and protect SEM / FIB / TEM-samples and calibration standards under vacuum. It protects valuable samples from air, moisture and dust. The superior EM-Storr vacuum container is constructed using high vacuum design guidelines and high vacuum compatible materials:

  • Vacuum grade aluminium, protective anodised coating only outside the vacuum chamber
  • Hardened safety glass lid Ø100mm x10mm; specified to withstand 7 bar
  • NBR O-ring with size: Ø85mm x Ø5mm cross section
  • All metal high vacuum valve with PTFE shaft seal and 6mm (1/4”) barbed hose connection
  • Silicon O-ring to hold the pin stubs or Hitachi stub adapters with size:  Ø3mm ID x Ø1.5mm cross section

The outside of the aluminium container is hard anodised for protection. To reduce outgassing and to hold vacuum for extended periods, the inside surface is machined vacuum grade aluminium with a glass lid. The EM-Storr vacuum desiccator is capable of reaching vacuum in the 10-4 mbar range. The vacuum connection for pump-down is a 6mm (1/4”) barbed hose fitting – compatible with 6mm thick wall silicon vacuum hose.  The EM-Storr vacuum containers are stackable; the octagonal design is optimised for handling, strength and weight.


Storage Capacity

The EM-Storr model 81 vacuum sample storage container comprise storage capacity for SEM pin stubs, Hitachi M4 cylinder stubs, TEM grids and FIB grids (the latter two in appropriate grid boxes). The pin stubs are securely held with small O-rings; stub adapters with M4 thread hold the Hitachi M4 threaded sample stubs. EM-Storr model 83 comprises a deeper vacuum chamber of 26mm x Ø80mm for large or bulk samples.
Storage capacity of the EM-Storr vacuum sample storage containers is:

Model Samples

Product #

Capacity

EM-Storr 81P

Pin stubs

13-001050-P

19xØ12.7mm or 7xØ25.4mm or 2xØ32mm or 1 x Ø38/Ø50/Ø63mm pin stub

EM-Storr 81H

Hitachi M4 stubs

13-001050-H

19xØ15mm or 7xØ25mm or 2xØ32mm or 1 x Ø50/Ø63mm cylinder stub

EM-Storr 81T

TEM grids

13-001050-T

2x30 TEM grids in the EM-Tec #28-0010130 GB-30 TEM storage box

EM-Storr 81F

FIB lift-out grids

13-001050-F

100 FIB lift-out grids in the EM-Tec #28-002100 FSB100S FIB grid storage box

EM-Storr 83L

Large / Bulk

13-001052-L

Maximum size 26mm x Ø80 mm

EM-Storr 110L

Bulk/large samples

13-1054-L

Large samples, maximum size Ø110 x 25mm



Operation

                Storing samples under vacuum

  • Place the EM-Storr vacuum sample container on a stable and flat surface
  • Make sure that the EM-Storr vacuum container is horizontal and level
  • Place the samples in the storage area: for SEM stubs use SEM stub gripper tweezers and push the pin in the holes. Select appropriate holes to maximise storage capacity
  • Check if O-ring surface is clean; if not, wipe clean with a lint-free cloth
  • Check if glass lid is clean; if not, wipe clean with a lint-free cloth
  • Place glass lid on the O-ring; center the lid so it doesn't touch the protective posts
  • Connect vacuum pump to the barbed hose connection on the vacuum valve using a 6mm vacuum hose
  • Make sure the vacuum valve is opened (turn counter clock-wise)
  • Switch the vacuum pump on and pump down (push down on the glass lid to provide an initial seal if needed)
  • When the required vacuum level has been reached, close the vacuum valve (turn clock-wise)
  • Switch the vacuum pump off and remove the 6mm vacuum hose.
  • The samples are now stored under vacuum

                Retrieving samples from vacuum

  • Place the EM-Storr vacuum sample storage container on a stable and flat surface
  • Make sure that the EM-Storr vacuum container is horizontal and level
  • Open vacuum valve (turn counter clock-wise) to vent; you might hear a hissing sound
  • Remove the glass lid; it might be needed to pull the glass lid to break the seal on the O-ring
  • Place the glass lid on a soft clean surface
  • The samples can be removed from the vacuum container


Maintenance

The EM-Storr vacuum sample storage container requires little maintenance:

  • Keep the sealing O-ring clean and dust free.
  • When the O-ring gets damaged; replace with an NBR O-ring size: Ø85mm ID x Ø5mm cross section O-ring.
  • When the O-ring dries out, remove, clean and use high vacuum grease to grease the O-ring; fully remove excess grease before replacing.
  • Over time, the PTFE seal on the vacuum valve may require some tightening; do not over-tighten.
  • The pin stubs and the Hitachi adapters are held by small O-rings underneath the sample plate; if they get damaged replace with a silicon O-ring size: Ø3mm ID x Ø1.5mm cross section.
  • If the glass lid gets damaged,  do not use it again and replace it with a new glass lid: #13-001050-G

 

TSB 13-001050 EM-Tec EM-Storr vacuum sample storage container   Revision 2



SEM Supplies

TEM Supplies

Calibration

Sample Preparation

AFM / SPM

  Product Menu with Images
  SEM Sample Stubs
  Carbon Tabs
  Sample Stub Adapters
  SEM Stage Adapters
  SEM Sample Holders
  SEM Preparation Stands
  Filaments / Cathodes
  Silicon Finder Grid
  Gatan 3View Pins
  FEI Volumescope Pins
  SEM Stub Storage Boxes
  Phenom Supplies
  JEOL NeoScope Supplies
  Hitachi TM Series Supplies
  Field & Lab Sampler Kits
  FlowView liquid sample Kit

Instruments

  Acoustic Enclosures
  Cressington SEM coaters
  TEM Sample Prep
  Diaphragm Pump
  Rotary vacuum Pump
  Precision diamond saw  
  TEM Grids
  TEM Support Films
  Silicon Nitride Films
  K-Kit Wet Cell Holder
  Graphene Films
  TEM Grid Boxes
  Cryo Grid Boxes
  TEM Sample Staining
  3mm Embedding Tubes
  Filaments/Cathodes
  Eyelash Manipulators

Cryo Supplies

  Cryo Grid Boxes
  Other Cryo Supplies

FIB Supplies

  FIB Lift-out Grids
  FIB Low Profile Stubs
  FIB Grid Holders
  FIB Pre-tilt Holders
  FIB Pre-tilt stubs
  FIB Grid Boxes
  SEM / FIB Magn. Calib.
  SEM Res. Test Spec.
  EDS / WDS Calibration
  TEM Calibration
  AFM / SPM Calibration
  LM Magn. Calibration

Vacuum Supplies

  Vacuum Gauges
  KF/NW Vacuum Parts
  KF/NW Vacuum Hoses
  Vacuum Oil and Grease
  Vacuum Sealant
  Diaphragm Pump
  Rotary vacuum Pump
  Vacuum Sample Storage
  Vacuum Pick-Up Pens

Sample Coating Supplies

  Sputter Targets
  Carbon Rods & Fibers
  Quartz QCM Crystals
  SEM Sample Coating Fluid

Evaporation Supplies

  Thermal Evaporation Sources
  Evaporation Materials
  Supports & Substrates
  SEM Preparation Stands
  Tweezers
  Probes & Picks
  Applicators & Swabs
  Plastic Transfer Pipettes
  Cutting Tools / Scissors
  Conductive Paint/Cement
  Conductive Tapes & Tabs
  Non-Conductive Adhesives
  Sample Storage
  Hand Tools
  Sorting Wire Mesh
  Preparation Surfaces
  Cleaning / Gloves
  Conductive Metal Powders
  Metallographic Sample Prep
  AFM/SPM Discs
  AFM/SPM Disc Pick-up Tool
  AFM/SPM Holders
  AFM/SPM Disc Storage
  Cantilever Tweezers
  AFM/SPM Discs Tweezers
  Nano-Tec Mica Discs
  HOPG Substrates

Light Microscopy

  Correlative Cover Slips
  Glass Microscope Slides
  Glass Cover Slips
  Quartz Microscope Slides
  Quartz Cover Slips
  Black Metal Slides
  Slide Storage Boxes
  LM Calibration
  Plastic Transfer Pipettes
  Optical Lens Tissue
  Glass Petri Dishes
  Digital Microscope
  PTFE Beakers